Skip to Content

PAS 2035:2023 Explained – What has changed?

What is the difference between the 2019 and the 2023 standards?
19 October 2026 by
Joseph Nelson

PAS 2035:2023 represents an important evolution of the UK's domestic retrofit framework.

Published in September 2023 and now the standard applicable to new PAS 2035 projects, the revised specification strengthens the move away from treating retrofit as a collection of individual energy efficiency measures and towards considering the whole dwelling as an interconnected building.

For housing associations, local authorities, principal contractors and installers, there are numerous technical changes to understand.

But one area deserves particular attention:

Retrofit Design.

PAS 2035:2023 places substantial responsibility on the Retrofit Designer. It also sets specific requirements for who can fulfil that role depending upon the measures and building involved.

This matters because retrofit design is not simply a document that needs a signature before installation can begin.

The Retrofit Designer is making decisions about how alterations to the building fabric, ventilation, airtightness, heating systems and renewable technologies interact with an existing building.

The question for clients should therefore not simply be:

"Do we have a Retrofit Designer?"

It should increasingly be:

"Who is actually designing our properties, and are they suitably qualified and competent to do so?"

What Changed With PAS 2035:2023?

PAS 2035:2023 introduced 15 principal revisions to the previous standard.

These include a stronger emphasis on consumer protection, provision for retrofit at scale using archetypes, a simplified risk assessment process and a greater emphasis on whole-dwelling retrofit.

There is also clarification of the Retrofit Coordinator's responsibilities, including site visits and recording non-compliance.

The Medium-Term Improvement Plan has moved from guidance to a requirement.

Airtightness strategies have been introduced for relevant projects.

Requirements concerning traditionally constructed and historically significant buildings have been clarified, including a new Annex E.

Ventilation requirements have been aligned more closely with Approved Document F.

Monitoring and Evaluation is considered throughout the project rather than simply at completion.

Climate resilience and adaptation requirements have been strengthened.

Moisture terminology has also been aligned with BS 5250:2021.

Collectively, these changes point in one direction:

PAS 2035 is increasingly about properly understanding, designing and managing changes to an existing building rather than simply specifying an individual energy efficiency measure.

That inevitably makes competent design more important.

Retrofit Design Is Now Much More Than Selecting a Product

The PAS 2035:2023 Design Best Practice Guidance prepared by ECMK in consultation with TrustMark and other scheme providers provides a useful indication of what is now expected from a compliant Retrofit Design.

Each design and its associated documentation should be property-specific.

The design should consider the existing building condition, proposed measures, products and systems, sequencing, interactions between measures, rain exposure, flood risk, fire safety, testing, commissioning and handover requirements.

Depending upon the project, the designer may also need to consider:

  • Thermal bridging
  • Airtightness
  • Ventilation
  • Overheating
  • Moisture
  • Existing defects
  • Planning constraints
  • Heritage significance
  • Heat loss
  • Heat generation
  • Solar orientation
  • Structural calculations
  • Crossflow ventilation
  • Building services
  • Interfaces between measures

This is important.

A Retrofit Design is not simply an insulation specification accompanied by several standard construction details.

It is the process of applying technical knowledge to a particular existing building.

The TrustMark design guidance makes this particularly clear by requiring designs and their corresponding documentation to be prepared and recorded as specific to the individual property.

PAS 2035:2023 Requires a Suitably Qualified Retrofit Designer

PAS 2035:2023 Annex A.3 establishes qualification requirements for Retrofit Designers.

The appropriate qualification route depends upon the project.

For example, a single proprietary measure may be designed by an appropriately trained and approved specialist designer or specifier of that system.

A single MCS-covered technology has its own route.

However, requirements increase as projects become more complex.

For relevant projects involving interacting fabric measures, multiple measures, high-rise or system-built properties, PAS 2035 identifies recognised professional qualification routes including:

  • Chartered Architectural Technologist – MCIAT or FCIAT
  • ARB-registered Architect
  • Professional Member of CIOB – MCIOB or FCIOB
  • Chartered Building Surveyor – MRICS or FRICS

Additional requirements apply where traditionally constructed buildings and heritage significance are involved.

Importantly, PAS 2035:2023 also requires the Retrofit Coordinator to review the Retrofit Designer's qualifications to establish that they comply with Annex A.3.

This is not an incidental administrative requirement.

The standard is deliberately linking the complexity of the design work with the competence of the professional responsible for undertaking it.

Qualification and Design Competence Are Not Necessarily the Same Thing

This is where the retrofit sector needs to be careful.

PAS 2035 establishes qualification thresholds.

Those thresholds are essential.

However, holding an accepted professional designation should not be interpreted as meaning that every individual holding that designation necessarily has identical design experience.

Consider MCIOB.

It is a respected professional membership and is expressly recognised by PAS 2035 as one of the qualifying routes for relevant Retrofit Designer appointments.

However, CIOB membership encompasses professionals working across a very broad construction industry.

Some may have extensive experience developing technical building designs.

Others may have spent their careers primarily in construction management, project management, commercial management or delivery.

The qualification can satisfy the applicable PAS requirement.

The separate question for a client should be:

Does the person actually undertaking my Retrofit Design have the appropriate skills, knowledge and experience for the design work involved?

The same principle should apply to every profession.

A professional title is evidence of a level of competence and professional standing. It should not replace consideration of an individual's actual experience relevant to the work being undertaken.

The Wider Construction Industry Is Moving in the Same Direction

This emphasis on individual competence is not unique to PAS 2035.

Changes introduced through the Building Regulations dutyholder regime have brought much greater attention to the competence of people undertaking design work.

The current Building Regulations framework requires designers to have the necessary skills, knowledge, experience and behaviours to undertake the work for which they are responsible.

RIBA's own guidance on Principal Designer competence similarly emphasises competence and the need for professionals to understand the limits of their abilities.

RIBA has noted that professionals should perform services only where they are sufficiently qualified through education, experience or training and have the resources required to undertake the work.

There is an important principle here that extends beyond any particular professional institution:

Design competence should relate to the design work actually being undertaken.

PAS 2035 should be approached in the same spirit.

The objective should not be to find the easiest professional designation that allows somebody's name to appear on a Retrofit Design.

The objective should be to appoint a professional who is genuinely competent to design the proposed works.

Who Actually Designed the Property?

This leads to another issue that clients should consider carefully.

Large retrofit organisations can employ substantial teams.

There is nothing inherently wrong with collaborative design or appropriately supervised junior staff. Indeed, developing the next generation of competent designers is essential.

But there is an important distinction between:

supporting a qualified designer

and

undertaking the design on behalf of somebody whose involvement is primarily a final review or signature.

The wider Building Regulations competence regime provides a useful parallel. Government guidance makes clear that a trainee who does not yet have the necessary competence cannot carry out design work unsupervised and must receive adequate supervision.

For PAS 2035 projects, clients should therefore understand how their design resource actually operates.

If a consultancy promotes the qualifications and experience of a particular professional, it is reasonable to ask:

Is that person actually involved in designing my properties?

Who reviewed the Retrofit Assessment?

Who selected the relevant technical details?

Who considered the building defects?

Who determined the ventilation requirements?

Who considered airtightness and thermal bridging?

Who decided whether the proposed construction was appropriate?

Who is taking professional responsibility for those decisions?

A senior professional reviewing work produced by a properly managed and competent design team can be a legitimate delivery model.

The concern arises where the person satisfying the advertised or required competence becomes little more than a signature at the end of a production process undertaken substantially by people who are not themselves competent to make those design decisions without appropriate supervision.

That risks turning professional competence into a compliance exercise rather than the quality safeguard it was intended to provide.

Why Direct Access to the Designer Matters

At PAS2035 Consultants Ltd, we believe there is significant value in clients knowing who is actually designing their retrofit projects.

Retrofit regularly produces questions that cannot be answered through templates.

A survey may identify an unusual wall construction.

The proposed insulation may interact with an extension.

Existing ventilation might be inadequate.

A thermal bridge may require a property-specific detail.

An existing damp issue might need remediation before insulation.

Solar PV may require structural consideration.

A traditional building may require a completely different approach to moisture and materials.

These are design decisions.

The person reviewing the information needs to understand the building and be capable of making or coordinating those decisions.

This is particularly important for housing associations and local authorities procuring large programmes.

The designer should not simply be a name on an organisational chart.

There should be a clear route between the client, Retrofit Coordinator, installer and the professional responsible for the design.

PAS2035 Consultants as the Overarching Retrofit Designer

PAS2035 Consultants Ltd is structured around this principle.

Our design capability is led by a Chartered Architectural Technologist (MCIAT) with specialist retrofit qualifications and experience.

That is significant because Architectural Technology is fundamentally a building design discipline.

It concerns the technical design of buildings, construction detailing, materials, performance, interfaces and translating design intent into buildable technical solutions.

For PAS 2035 programmes, this provides a strong foundation for acting as an overarching Retrofit Designer.

That does not mean pretending that one professional personally replaces every specialist involved in a modern retrofit project.

Quite the opposite.

Some measures appropriately require specialist input.

Solar PV may involve an MCS designer and structural calculations.

A heat pump may require specialist heating design.

An EWI system may have proprietary system details.

Complex structural matters may require a structural engineer.

Fire, conservation or building services issues may sometimes require further specialist expertise.

The role of the overarching designer is to bring those inputs into one coordinated property-specific Retrofit Design.

PAS 2035 itself recognises specialist design routes for particular measures.

The important issue is ensuring those individual designs do not exist as isolated documents.

One Dwelling, One Coordinated Design

Consider a property receiving:

External Wall Insulation + Loft Insulation + Solar PV + Ventilation Improvements + Heating Controls.

Several specialists might contribute.

The EWI system designer may provide system details.

The PV designer may determine array layout and electrical configuration.

A structural assessment may establish whether the roof can accept the additional load.

A ventilation specialist may provide equipment performance information.

But somebody still needs to consider the dwelling as a whole.

How does the EWI terminate at the roof?

How does the loft insulation meet the external wall insulation?

Is continuity of insulation achieved?

What happens to existing ventilation terminals passing through the EWI?

Will the measures alter airtightness?

Does ventilation need upgrading?

Does the PV installation affect roof ventilation or weathering?

Are there existing defects that must be resolved first?

Does sequencing matter?

Are the specified measures collectively compatible with the intended outcomes?

This is where an overarching Retrofit Designer adds value.

Rather than allowing several technically correct specialist designs to sit alongside each other without coordination, the project can have one property-specific design bringing those interfaces together.

Why PAS2035 Consultants Can Design Across Different Measure Packages

PAS 2035 does not require the overarching professional to personally perform every specialist calculation.

It requires the correct competence to be applied to the work.

That distinction is important.

PAS2035 Consultants can therefore act as the overarching designer while incorporating specialist information where required.

Our role can include reviewing and coordinating:

  • External Wall Insulation
  • Internal Wall Insulation
  • Room-in-Roof Insulation
  • Loft Insulation
  • Cavity Wall Insulation
  • Underfloor Insulation
  • Windows and doors
  • Ventilation
  • Airtightness
  • Solar PV
  • Heating systems
  • Heat pumps
  • Controls
  • Heritage considerations
  • Overheating
  • Thermal bridging

Where specialist design is required, that specialist contribution can form part of the coordinated Retrofit Design rather than becoming a disconnected piece of information elsewhere in the evidence pack.

This provides a clear distinction between designing everything personally and taking responsibility for coordinating the complete design.

The latter is increasingly important as retrofit packages become more complex.

PAS 2035:2023 Makes Property-Specific Design Harder to Ignore

One of the clearest messages within the 2023 design guidance is the emphasis on property-specific information.

For example, the guidance requires property-specific thermal bridge details and says the design should identify which details apply at particular locations.

For fabric improvements, the Retrofit Designer must develop an airtightness and air leakage testing strategy.

The designer must consider overheating.

Existing building defects need to be identified.

Ventilation adequacy needs to be assessed in relevant circumstances.

The exact model of products should be identified where product ranges contain several alternatives.

Interactions between measures need to be managed.

The sequence of installation needs consideration where incorrect sequencing could adversely affect the building or measures.

These requirements demand professional judgement.

A library of standard details is useful.

It is not, by itself, a property-specific Retrofit Design.

What Should Housing Associations and Councils Ask Their Retrofit Designer?

Procurement should therefore move beyond asking whether a tenderer "has a Retrofit Designer".

Clients should understand how the design will actually be produced.

Useful questions include:

  1. Who is the named Retrofit Designer responsible for our programme?
  2. What professional qualification allows them to undertake the proposed design work under PAS 2035 Annex A.3?
  3. What is their actual background in building design?
  4. Will that professional personally undertake or directly oversee our designs?
  5. Which tasks are delegated to junior staff?
  6. How are those staff supervised?
  7. How are specialist designs incorporated into the overall Retrofit Design?
  8. Who resolves conflicts between specialist designs?
  9. Can our Retrofit Coordinators and project team speak directly to the designer?
  10. Who takes responsibility when site conditions require the design to change?

These questions are particularly important where a bidder promotes the experience of senior individuals during procurement.

Clients should understand whether those professionals will genuinely participate in the programme after appointment.

PAS 2035:2023 Should Raise the Status of Retrofit Design

PAS 2035 has sometimes been perceived as primarily a Retrofit Coordinator-led process.

The Coordinator unquestionably has a critical role.

But coordination and design are different professional functions.

The Retrofit Coordinator establishes and manages the overall PAS process.

The Retrofit Designer develops the technical solution for the building.

PAS 2035:2023 makes the significance of that second function increasingly difficult to overlook.

When we insulate a wall, change a ventilation system, improve airtightness, install renewable technology or alter the thermal envelope, we are changing how a building performs.

Those decisions deserve proper design.

Our Approach at PAS2035 Consultants Ltd

PAS2035 Consultants Ltd provides specialist Retrofit Design and Retrofit Coordination services for domestic retrofit programmes.

Our approach is deliberately design-led.

We can act as the overarching PAS 2035 Retrofit Designer, bringing together assessment information, proposed measures, specialist designs, product information and property-specific technical requirements into one coordinated design.

Where specialist expertise is required, we recognise it and incorporate it.

Where a property requires a different solution, we design for the property rather than forcing the property into a standard template.

And importantly, clients can engage with the professional responsible for their design.

For housing associations and local authorities, this provides a clear technical design function sitting between programme objectives and installation.

For principal contractors and PAS 2030 installers, it provides access to a suitably qualified PAS 2035 design resource without necessarily building an entire multidisciplinary design department internally.

The Direction of Travel Is Clear

PAS 2035:2023 is about much more than updating forms and processes.

It continues the retrofit industry's transition towards a professional, whole-dwelling approach.

That means assessment matters.

Coordination matters.

Installation competence matters.

But design matters too.

The strongest interpretation of PAS 2035's competence requirements is therefore not to ask:

"Who can sign this design?"

It is to ask:

"Who is competent to design this building?"

That difference may appear subtle.

In practice, it is fundamental.

PAS2035 Consultants Ltd believes the future of high-quality retrofit lies in qualified, accountable designers working directly with clients, Retrofit Coordinators, specialists and installers to produce genuinely property-specific solutions.

Because ultimately, the objective of PAS 2035 is not to produce a compliant evidence pack.

It is to produce a better building.

Further Reading

PAS 2035:2023 Retrofit Design Best Practice Guidance

Detailed guidance prepared by ECMK in consultation with TrustMark and other scheme providers covering property-specific designs, designer qualifications, ventilation, airtightness, thermal bridging and other design requirements.

TrustMark – PAS 2035:2019 / PAS 2035:2023

Information covering the transition to PAS 2035:2023 and the wider Retrofit Standards Framework.

RIBA – Principal Designer Competency Requirements

Useful wider-industry guidance on design competence, professional responsibility and understanding the limits of an individual's competence.

GOV.UK – Design and Building Work: Meeting Building Requirements

Government guidance explaining competence requirements for designers, including skills, knowledge, experience and behaviours and the supervision of people undertaking design work while in training.

Joseph Nelson 19 October 2026
Share this post
Tags
Archive